How many circuits do you usually need in a kitchen in Ontario?
How many circuits does a kitchen need? — How many circuits do you usually need in a kitchen?
Plan a normal house kitchen circuit by circuit: the fridge gets its own branch circuit (Rule 26-654), the counter plugs go on their own 20 A or split 15 A circuits that feed nothing else (Rules 26-656 and 26-722), and the range gets its own 240 V circuit with a 14-50R receptacle (Rule 26-744). Built-in appliances such as a dishwasher or enclosed microwave each add a circuit — count the counter first, then the appliances, in the book under Rules 26-654, 26-656 and 26-722.
⚑ WATCH OUT FOR THIS
Count the counter first, then the appliances. Counter plugs within 1.5 m of the sink also need GFCI — see the kitchen counter GFCI check. Island and peninsular counters have their own plug rules, so check Rules 26-656 and 26-722 in the book for the exact count on your layout.
Code book: OESC 29th ed. (2024) — Rules 26-654, 26-656, 26-722 & 26-744: Kitchen branch circuits — dwelling units
Help only — check the rule in the real code book before you trust it. This does not take the place of an ESA inspection.
This is one answer. The whole book list is inside.
This is one of 74 checks in the app. Subscribers get all 74 plain-language checks with rule numbers, ESA notes, and the 24-item pre-inspection checklist of what inspectors write up most — plus Ask: type any electrical question and get a plain-language answer with the rule number.
Photo Check: snap a photo of your work in the app and get a second look — what can be seen, what to check more closely, and the code rule for each flag.
CAD $9.99/month — first month free for new subscribers. Cancel anytime. One account works on your phone and your computer, iPhone and Android.
Start free month Open the app